Abbott Architect Analyzer I2000 User Guide

Abbott Architect Analyzer I2000 User Guide Average ratng: 3,7/5 5643 votes
  1. Abbott Architect I2000 Operation Manual

Name of instrument/First year sold/Where designed ARCHITECT i2000SR/2002, i4000SR/2007/U.S. Country where manufactured/Where reagents manufactured Singapore/U.S., Europe Number of units in clinical use in U.S./Outside U.S. — Operational type/Model type/Sample handling system batch, random access, continuous random access/ floor standing/track and LAS Dimensions in inches (H × W × D)/Instrument footprint in sq. Feet 48 × 61 × 49/20.7 (i2000SR) Tests available on instrument in U.S.

Instructor's Solutions Manual for Optimization in Operations Research, 2nd Edition. Rardin, University of Arkansas. ©2017| Pearson. Share this page. Research 2nd edition ronald l rardin solution manual completed download. 10 optimization in operations research 2nd edition rardin solutions. Optimization in operations research solutions manual. Jan 18, 2016 - Optimization in Operations Research Ronald Rardin Solutions. Solution Manual for book of same name. Documents Similar To Optimization in Operations Research Ronald Rardin Solutions. Operation Research Taha Solution Manual. Yafet Ghirmai.

— Tests not available in U.S. But submitted for clearance — Tests not available in U.S.

Abstract Serum hepatitis B virus (HBV) markers are the most important data for epidemiological screening and clinical diagnosis of HBV infection, especially in endemic areas. We compared the results of the Roche Modular Analytics E170 assay, the Abbott Architect i2000 assay, and an immunoradiometric assay (IRMA) for HBV surface antigen (HBsAg), anti-HBV surface antigen (anti-HBs), HBV e antigen (HBeAg), and anti-HBV e antigen (anti-HBe). A number of serum samples (264, 263, 224, and 202 for HBsAg, anti-HBs, HBeAg, and anti-HBe, respectively) were studied. For samples giving discrepant results for HBeAg between methods, real-time PCR assays were performed. The concordance rates among the three methods were high for HBsAg (100%) and HBeAg (94.6), but low for anti-HBs (91.6%) and anti-HBe (82.2%).

For anti-HBs, which could be measured quantitatively by the Modular E170 and Architect i2000 procedures, discrepant results were observed at low levels of anti-HBs. For anti-HBe, the positive rate was highest with Modular E170 (60.9%) followed by the IRMA kit (54.1%) and Architect i2000 (51.0%). This study shows substantial differences between the assay results by the three methods, which should be taken into account in determinations of serum HBV markers. Introduction Hepatitis B virus (HBV) infection is a major global public health problem. Of the approximately 2 billion people who have been infected worldwide, more than 350 million are chronic carriers of HBV. Approximately 15 to 40% of infected patients will develop cirrhosis, liver failure, or hepatocellular carcinoma (HCC). In particular the HBsAg seroprevalence in the Western Pacific (China, South Korea, and Taiwan) ranges between 10 and 12%.

Determination of serum HBV markers is crucial for rapid screening and clinical diagnosis of HBV infection, particularly in regions with high prevalence. Recently, automated analyzers, such as Roche Modular Analytics E170 (Modular E170) and Abbott Architect i2000 (Architect i2000) have been developed. However, there are few reports that have assessed the performance of these analyzers. In this study, we compared the test results of HBV serologic markers as measured by an immunoradiometric assay (IRMA), the Modular E170 assay, and the Architect i2000 assay.

Measurement of four serum HBV markers. The IRMA kit (North Institute of Biological Technology, Beijing, China), a solid phase radioimmunoassay kit, was used according to the manufacturer’s instruction. First, serum is incubated with beads coated with monoclonal antibody. After 3 washing steps, the second antibody conjugated with I 125 reacts with the analytes fixed on the beads. Radioactivity is measured in counts per min (cpm) using a Packard gamma counter (GMI, Inc., Minneapolis, MN, USA). All four HBV markers are measured by the qualitative method.

Where the cpm value of the sample exceeds a cut-off value, the result is positive for HBsAg, anti-HBs, and HBeAg; and where the cpm value of the sample is less than the cut-off value, the result is positive for anti-HBe. The Modular E170 analyzer (Roche Diagnostics, Mannheim, Germany) uses an electrochemiluminescence immunoassay (ECLIA); serum anti-HBs is determined quantitatively while serum HBsAg, HBeAg, and anti-HBe are determined qualitatively. HBsAg, HBeAg, and anti-HBe are interpreted using the ratio of the sample signal to the cut-off signal (S/CO). Results of anti-HBs with concentration values ≥10 IU/L are positive and the upper detection limit is 1,000 IU/L.

The Architect i2000 analyzer (Abbott Diagnostics, Abbott Park, IL, USA) uses a chemiluminescent microparticle immunoassay (CMIA); serum HBsAg and anti-HBs are determined quantitatively, while serum HBeAg and anti-HBe are determined qualitatively. Positive cut-offs values for HBsAg and anti-HBs are ≥0.05 and ≥10 IU/L, respectively; the upper detection limits for HBsAg and anti-HBs are 250 and 1,000 IU/L, respectively. HBeAg and anti-HBe are interpreted using a ratio of the sample relative light unit (RLU) rate to the cut-off RLU (S/CO). Real-time polymerase chain reaction. For samples showing discrepant results for HBeAg among the IRMA and two automated analyzers, a real-time PCR assay was performed using HBV PCR kits (Abbott Diagnostics, Hamburg, Germany) and an ABI PRISM 7000 HT Sequence Detection Systems (Applied Biosystems, Foster City, CA, USA). DNA extraction was performed using the Abbott DNA Sample Preparation System (Abbott Diagnostics, Wiesbaden, Germany) following the manufacturer’s instructions. The prepared DNA samples were stored at −20°C until use.

For HBeAg, the concordance rate between the two automated analyzers was higher than for each with the IRMA (Table 3). Of 224 samples, 7 were negative only by the IRMA, 2 were positive only by IRMA, and for these 9 cases real time PCR was performed. Six of 9 cases showed positive results in real-time PCR. For these 6 samples, IRMA was positive in only 1, whereas with Modular E170/Architect i2000, 5 gave positive results (Table 4). Of the 3 real-time PCR negative samples, IRMA gave 2 negative results and Modular E170/Architect i2000 gave 1 negative result. Concordance rates of IRMA and Modular E170/Architect i2000 assays with real-time PCR were 33.3% (3/9) and 66.6% (6/9), respectively.

Discussion Determination of serum HBV markers is crucial for rapid screening and clinical diagnosis of HBV infection, particularly in regions with high prevalence. However, in determination of serum HBV markers, discrepancies among test results from different types of immunoassay analyzers, which could affect the accuracy of epidemic screening and clinical diagnosis, have been reported.

In this study, we compared the results for HBsAg, anti-HBs, HBeAg, and anti-HBe among two automated immunoassay analyzers (Modular E170, Architect i2000) and an IRMA assay. In determination of HBsAg, the concordance rate of the three methods was 100%, but only Architect i2000 could perform quantitative analysis. This quantitative measurement of HBs titers may be an easy and economical reference for HBV replication, because the change in HBsAg concentration correlates well with the changes in HBeAg and HBV DNA levels ,.

Analyzer

Abbott Architect I2000 Operation Manual

I2000

Serum anti-HBs is important for confirmation of protective immunity after vaccination and recovery after HBV infection. An anti-HBs concentration 10 IU/L, is considered to be protective against HBV infection. Therefore, low titers of anti-HBs must be accurately determined for evaluating the effect of vaccination and booster injections. Modular E170 and Architect i2000 can perform quantitative analysis, and there was good correlation (r = 0.918, concordance rate = 97.3%) between these two analyzers. These findings are in agreement with another report. For comparison with RIA, Wang et al reported that anti-HBs titers measured by EIA correlated well with the results of RIA.

However, inconsistent results have been reported in other studies 3, 8–10. These differences may be related to the various sources of reagents and to the different HBV vaccines. There are fewer reports comparing serum HBeAg and anti-HBe assays than of HBsAg and anti-HBs assays. HBeAg seroconversion is the short-term goal of antiviral therapy in chronic hepatitis B , and the fall of HBeAg levels during early treatment is an important independent predictor of response. In the present study, the concordance rate of HBeAg with the three analyzers was high (94.6%), and it was higher between Modular E170 and Architect i2000 (98.7%) than for each with IRMA. In addition, although the HBV DNA level does not always correlate with the HBeAg level, the concordance rate of HBeAg results from Modular E170/Architect i2000 with the HBV DNA level was higher than that of IRMA.

For anti-HBe, the positive rate was highest with the Modular E170 assay, which is consistent with a previous study. Of the 16 cases positive only by Modular E170, 15 were HBeAg-positive with all three analyzers, suggesting false positive results with the Modular E170 assay.

In conclusion, the concordance rate was highest for HBsAg, followed by HBeAg, anti-HBs, and anti-HBe. The concordance rate was greater between the two automated analyzers than those of each with IRMA for anti-HBs and HBeAg and the positive rates were highest with the Modular E170 assay for anti-HBe.

This study shows substantial differences between the assay results by the three methods, which should be taken into account in determinations of serum HBV markers.